Matters needing attention when assembling diesel generator sets?
Release Time:
2024-03-18
Many customers buy diesel generator sets in the assembly process is not very much attention to some details, such as the assembly environment is very dusty, into the unit equipment buried friction damage hidden trouble, and for example, the assembly environment is relatively humid, easy to let moisture into the equipment inside.
Many customers buy diesel generator sets in the assembly process is not very much attention to some details, such as the assembly environment is very dusty, into the unit equipment buried friction damage hidden trouble, and for example, the assembly environment is relatively humid, easy to let moisture into the equipment inside. For these overlooked details, made a summary:
Generator set assembly need to pay attention to:
1, the installation location needs to be well ventilated, generator end should have enough air inlet, diesel engine end should have a good air outlet. The air outlet area should be greater than the water tank area 1.5 times more.
2, the installation of the surrounding area should be kept clean, avoid placing in the vicinity of corrosive gases and vapours that can produce acidic, alkaline and other items. Conditional should be equipped with fire extinguishing devices.
3, in the indoor use, must be the exhaust pipe through the guide outdoor, the pipe diameter must be ≥ silencer diameter of the smoke pipe, connected to the pipe elbow should not be more than 3, to ensure that the exhaust smoke smooth, and should be tilted downward 5-10 degrees, to avoid rainwater injection; if the exhaust pipe is installed vertically upward, must be installed with a rain cover.
4、When the foundation is made of concrete, a level ruler should be used to measure its level during installation, so that the unit can be fixed on a horizontal foundation. There should be special anti-vibration pads or foot bolts between the generator set and the foundation.
5, the generator set shell must have a reliable protective grounding, the need to have a neutral point of direct grounding of the generator, then must be carried out by professionals neutral grounding, and the configuration of lightning protection devices, it is strictly prohibited to use the utility grounding device for the neutral point of direct grounding.
6, the generator and the utility of the two-way switch must be very reliable, in order to prevent reverse power. The reliability of the two-way switch wiring needs to be approved by the local power supply department's inspection.
Focus on the above details, can effectively avoid unnecessary damage to the equipment before use, the subsequent use can also be carried out normally, the damage and corrosion to play a certain preventive role.